An aluminum composite panel may look like a simple sheet, but a reliable specification must describe its total thickness, aluminum skins, core, coating, dimensions and fabrication requirements. A request for “4 mm ACP” alone leaves critical variables open and makes quotations difficult to compare. This guide explains the main building grade ACP specifications and shows how to match them to facades, signs, interiors and transport applications without treating a typical industry value as a universal requirement.
ACP consists of two thin aluminum skins bonded to a central core. Adhesive films create the bond, while a factory-applied coating protects and colors the visible face. A removable film protects the surface during fabrication and installation. Each layer contributes to performance: skins influence rigidity and forming, the core affects weight and fire behavior, bonding affects peel resistance, and coating affects weathering. A thicker panel is not automatically a better panel. Poor bonding or an unsuitable coating can undermine a thick sheet, while a correctly engineered thinner composite may outperform a heavier alternative in its intended application.

Total panel thickness is commonly offered in several millimetre grades, with thinner sheets used for displays or interiors and thicker composites used where greater rigidity is required. Skin thickness is quoted separately in millimetres and deserves equal attention. Two 4 mm panels can contain different aluminum gauges, producing different handling, fabrication and mechanical behavior. Routed-and-folded corners, large cassette modules and high-wind facades need engineering appropriate to their loads and support spacing. Do not copy a skin gauge from another project without checking alloy, temper, fixing design and fabrication trials. FEITENG can confirm available combinations against your drawings and quantity.
Common ACP cores include polyethylene and mineral-filled fire-rated formulations. Product names such as FR, B1 or A2 should be linked to an identifiable test report, standard, scope and valid document rather than used as generic marketing labels. Requirements also differ between a sheet reaction-to-fire classification and the performance of a complete external wall assembly. Our guide to fire-rated ACP panel classes explains the terminology in more detail. Always have the project fire consultant confirm the required evidence for the building height, occupancy and jurisdiction. Coating selection, panel thickness and core certification should remain separate lines in the specification.
Standard stock sizes can simplify ordering, while custom lengths or widths may reduce joints and fabrication waste. Before choosing a large format, check transport limits, lifting access, storage flatness and the fabricator’s equipment. Weight should be calculated from the confirmed construction rather than estimated from total thickness alone; mineral cores and heavier aluminum skins change the result. Ask the supplier for the datasheet weight, dimensional tolerances and packaging method. These figures affect container loading, structural calculations and installation labor. A cutting list grouped by elevation also helps keep color batches consistent and reduces offcut waste.
Exterior surfaces require a coating appropriate for UV, moisture and local pollutants, while interior finishes can prioritize appearance and budget. PVDF and polyester should not be treated as interchangeable names for paint. Record the coating system, color reference, gloss, texture and any printing requirement. Review physical samples under real lighting and define an approved batch for large elevations. For ink-ready surfaces, see our digital printing ACP specification. For branded displays, signage grade ACP provides a more application-focused starting point than a generic facade sheet.
| Application | Specify first | Verify before order |
|---|---|---|
| Exterior facade | Skin, core, exterior coating, cassette design | Wind engineering, fire evidence, color batch |
| Outdoor signage | Flatness, coating, dimensions | UV exposure, fixing, print compatibility |
| Interior wall | Thickness, finish, core requirement | Substrate, adhesive, room fire rules |
| Digital display | Ink-ready face, flatness, protective film | Ink cure, adhesion test, handling |
| Transport interior | Weight, skin, laminate or coating | Transport standard, vibration, cleaning |
For transport-specific construction, review vehicle and ship grade ACP. Wet-area projects should instead begin with our waterproof bathroom wall panel requirements and complete installation detailing.
Inspect packaging, labels and panel faces before signing for a shipment. Confirm that the delivered dimensions, thickness, coating and core match the approved submittal, and isolate mixed batches until their use is agreed. Measure representative sheets with calibrated tools rather than relying only on a catalogue value. During first-off fabrication, check routing depth, edge condition, bending behavior and peel or coating defects. Store sheets flat on a clean support with protective film intact and keep them away from standing water or site contamination. A short receiving record with photographs can prevent disputed material from reaching the installation line.
Give every bidder the same application, dimensions, quantity, construction, coating, color, core evidence and delivery terms. Ask them to state exclusions and identify any proposed alternative in writing. A low quotation based on thinner skins or a different coating is not equivalent to the requested panel. Include fabrication drawings when cassettes or routed parts are required, because cutting yield and processing can materially affect the final price. Finally, align inspection documents with the shipping marks so that project teams can trace each approved batch after arrival.

Confirm sheet and fabrication tolerances before releasing a full cutting list. Small size differences can accumulate across joints and openings. Agree how diagonal, edge and formed-part dimensions will be measured, then retain the approved first-off component.
Include back-face coating and protective film in the order when they affect corrosion, printing or handling. Small omissions can become visible after fabrication, when replacement is expensive.
No single thickness suits every facade. Skin gauge, panel size, support spacing, wind load, core and fabrication all matter. Use 4 mm as a discussion point only, then confirm the engineered system and documented product construction.
Panel thickness includes both aluminum skins and the core. Skin thickness measures only one aluminum face. A complete specification states both values, along with alloy, coating and core, so suppliers quote equivalent products.
Use the confirmed manufacturer datasheet for the exact construction. Total thickness alone is insufficient because aluminum gauges and core densities vary. Weight calculations should support handling and engineering, not replace them.
Custom sizes may be available depending on product, finish and quantity. Check minimum order requirements, tolerances, packaging and fabrication yield. A customized sheet is worthwhile only when transport and installation can accommodate it safely.
Request a current datasheet, coating details, relevant test reports, warranty terms, color approval and fabrication guidance. Regulated projects may require additional traceability and assembly evidence. Keep document revision numbers with the approved submittal.
FEITENG’s manufacturing experience dates to 1994, and project-specific values should always be confirmed against current product documents. For help turning a drawing into a comparable quotation, use our ACP technical resources or send your ACP specification to FEITENG with dimensions, application and required standards.